Computer Room Design Revised
  • Intelligent surge protector for computer room PDU

    Intelligent surge protector for computer room PDU

    Intelligent PDUs leverage several types of protection devices to protect server devices from any potential surges. It incorporates surge protection modules, including metal. That's why Schleifenbauer has integrated the highest quality surge protection (type 3) from Dehn into our rack PDUs, directly at your critical end equipment. In the Netherlands alone, around 300,000 lightning strikes are recorded. PDU provides safe power distribution and can be installed horizontally or vertically Production Intelligent monitoring PDUs are complete and versatile, and can meet the needs of high-end server rooms and data centre software intelligent power distribution and environmental monitoring systems.


  • Cold aisle outlet air temperature in the computer room

    Cold aisle outlet air temperature in the computer room

    In an open aisle configuration, supply and return air temperatures will typically be set at 12°C and 24°C respectively. Because air mixing occurs, the room has to be kept at an artificially low temperature. Raised floors are commonly used in data centers to provide an efficient way to deliver cold air from the computer room air conditioner (CRAC) unit to server racks. Cold aisles are ormed by the space. Hot aisle and cold aisle containment are foundational concepts in data center design. In this guide, we'll break down how hot aisle and cold aisle configurations. Beyond implementing basic measures such as sealing moisture out of the data center and improving air flow, aisle containment to prevent the mixing of hot and cold air stands out as a method that can dramatically reduce energy costs, minimize hot spots and improve the carbon footprint of data. Traditional open aisle data centers use perimeter PAC (precision air conditioning) or CRAC (computer room air conditioning) units to channel cold air up through a raised floor void via grilles positioned in front of the IT cabinets.

    [PDF Version]
  • What is the function of hot aisles in the computer room

    What is the function of hot aisles in the computer room

    Hot aisle containment captures hot exhaust air from server equipment and directs it back to cooling units through physical barriers like doors, panels, and ceiling systems. When implemented correctly, they improve efficiency, reduce energy consumption, extend equipment life, and enhance overall reliability. How does Hot Aisle Containment work? As the name suggests, a hot aisle containment system. The hot aisle /cold aisle data center layout was originated by IBM in 1992 and it is one of the oldest ways to save energy in the data center. By preventing the mixing of hot exhaust air with cold intake air, these hot aisle containment data center systems keep data centers running smoothly. Hot aisle containment (HAC) and cold aisle containment (CAC) are the most efficient ways of preventing your servers from overheating and these systems are currently being used in data centers all around the world. Computer servers will generate much heat when they are operating. The HAC system directs the upward airflow to an AC return system such as a drop-ceiling void.

    [PDF Version]
  • The function of the optical cable inlet panel in the computer room

    The function of the optical cable inlet panel in the computer room

    An optical Distribution Frame (ODF) or patch panel is the starting point for optical cables, most commonly found in rack cabinets in Head End (HE)/Central Office (CO)/Point of Presence (POP)/Data Centre (DC) or smaller cabinets or enclosures. The fiber patch panel, also known as an optical distribution frame (ODF), plays a key role in terminating, distributing, and protecting optical fibers. With the rise of high-density data centers and FTTH systems, traditional ODF designs are being complemented by MPO/MTP-based fiber patch panels. Fiber bend limiting brackets and retaining rings that protect, route, and organize the fiber cables are also included. The 18T OCEF will accommodate either moisture-tight cable connectors or hole seals. At CO, the purpose is to provide interconnection between outside cables to Optical Equipment by using fibre patch cord. Whether in data centers, telecom central offices, or enterprise network rooms, ODFs enable efficient fiber management.

    [PDF Version]
  • How to ground fiber optic cables in a computer room

    How to ground fiber optic cables in a computer room

    Follow the J-STD-607-A and TIA-942 standards and place a grounding bar in each data center, telecommunications room, etc. Fiber optic cable transmits data as light through glass or plastic strands, which means the fiber core itself carries no electrical current and requires no grounding. The critical distinction lies in. This Applications Engineering Note (AE Note) discusses conventional bonding and grounding practices for conductive fiber optic cable and hardware installations within the scope of the National Electrical Code (NEC). Those risks are possible serious injury, fire, and even death. Are Bonding and Grounding the Same Thing? Nope. In fact. The simplest way to design a network that avoids traditional copper cabling problems and the additional associated costs is to choose an all-dielectric fiber optic cable.

    [PDF Version]