Deep Dive Into World
  • Madagascar Cold Aisle High Density

    Madagascar Cold Aisle High Density

    DAMAC's cold aisle containment systems are a great fit for high-density data centers. When implemented correctly, they improve efficiency, reduce energy consumption, extend equipment life, and enhance overall reliability. In this guide, we'll break down how hot aisle and cold aisle configurations. Rising energy cost and energy consumption has prompted data centers to consider hot aisle and cold aisle containment strategies, which can improve the energy efficiency and maintain the recommended level of inlet air temperature to IT equipment. It manages airflow at the source, increases the cooling e ciency and significantly lowers down operating costs. Beyond implementing basic measures such as sealing moisture out of the data center and improving air flow, aisle containment to prevent the mixing. Through the use of computational fluid dynamics (CFD) simulations, three different airflow strategies were evaluated and improved: underfloor precision air conditioning, inter-column air conditioning, and backplane air conditioning.

    [PDF Version]
  • Cold aisle outlet air temperature in the computer room

    Cold aisle outlet air temperature in the computer room

    In an open aisle configuration, supply and return air temperatures will typically be set at 12°C and 24°C respectively. Because air mixing occurs, the room has to be kept at an artificially low temperature. Raised floors are commonly used in data centers to provide an efficient way to deliver cold air from the computer room air conditioner (CRAC) unit to server racks. Cold aisles are ormed by the space. Hot aisle and cold aisle containment are foundational concepts in data center design. In this guide, we'll break down how hot aisle and cold aisle configurations. Beyond implementing basic measures such as sealing moisture out of the data center and improving air flow, aisle containment to prevent the mixing of hot and cold air stands out as a method that can dramatically reduce energy costs, minimize hot spots and improve the carbon footprint of data. Traditional open aisle data centers use perimeter PAC (precision air conditioning) or CRAC (computer room air conditioning) units to channel cold air up through a raised floor void via grilles positioned in front of the IT cabinets.

    [PDF Version]
  • Equipment used for cold aisle installation in computer room

    Equipment used for cold aisle installation in computer room

    Traditional open aisle data centers use perimeter PAC (precision air conditioning) or CRAC (computer room air conditioning) units to channel cold air up through a raised floor void via grilles positioned in front of the IT cabinets. Flexible design allows the containment system to adapt as the computer room evolves. An enormous amount of energy is used every day to maintain an acceptable intake temperature to the IT equipment. Essentially creating a room within the aisle, the system helps keep hot and cold air separated to make existing air conditioning systems in data center and edge-of-network. Aisle containment is a critical airflow management strategy that separates cold supply air from hot exhaust air within a data center.

    [PDF Version]
  • How deep should the fiber optic panel be to be used

    How deep should the fiber optic panel be to be used

    The International Telecommunication Union (ITU) and Institute of Electrical and Electronics Engineers (IEEE) recommend a minimum depth of 0. 6 meters for urban areas and 1. 0 meters for rural or agricultural zones to protect against frost, plows, and erosion. The depth can vary from location to location, based on a number of different environmental influences. In this guide, we'll break down depths commonly used, influencing factors, best practices, challenges, and discuss emerging trends. That way you'll have the knowledge you need to ensure an. The short answer, based on general industry standards and the National Electrical Code (NEC), is that fiber optic cable is typically buried between 24 inches (60 cm) and 30 inches (76 cm) deep. However, simply hitting this depth isn't enough to guarantee your network survives. A crucial aspect of this process is determining the appropriate burial depth for the cable.

    [PDF Version]
  • There is an electrical distribution box on the side of the building

    There is an electrical distribution box on the side of the building

    North American distribution boards are generally housed in enclosures, with the positioned in two columns operable from the front. Some panelboards are provided with a door covering the breaker switch handles, but all are constructed with a dead front; that is to say the front of the enclosure (whether it has a door or not) prevents the operator of the circuit breakers from contacting live electrical parts within. carry the current from incoming line (hot) conductors to the breakers.


  • Wiring exits from the side of the household distribution box

    Wiring exits from the side of the household distribution box

    ‌Wiring Direction‌: Wiring between the main circuit breaker and each branch circuit breaker in the box generally goes on the left, and the wiring out of the distribution box generally goes on the right. ‌Binding Requirements‌: The wires should be bound with. Hey, in this article we are going to see the Single Phase Distribution Box Wiring Diagram and Connection Procedure. A distribution board or distribution box is where the main power supply is distributed to multiple loads. This prevents arc faults and ensures safety when modifying or inspecting current paths.


  • There is an optical fiber at the bottom of the router

    There is an optical fiber at the bottom of the router

    The ONT – Optical Network Terminal (also known as the modem) is connected to the Termination Point (TP) via an optical fiber cable. Using an Ethernet cable, it connects to your router and converts light signals from your TP's fiber optic line into electronic signals that your router. It's an OTN box converts the fiber cable from outside and turns into ethernet that goes into your router but this is an old style OTN box but I know a few homes that has this box and still works no problem if you have problems contact your ISP and they can replace the OTN with a newer model. If you are a fibre customer, it's likely you'll have an Openreach modem (or ONT) installed. This white box connects to a fibre-optic cable that runs to your house and enables you to access our FTTP fibre network for broadband and voice. There are several lights on the ONT, when these lights change. The fiber optic cable does not plug directly into a standard home router because the signal type must be translated. Its primary, and most critical, function is to act as a signal converter.

    [PDF Version]
  • What access switches support hot standby

    What access switches support hot standby

    In an HSRP setup, multiple routers or layer 3 switches work together to present a virtual IP address and MAC address as a single default gateway to the connected devices. One router assumes the active role and forwards traffic, while the others remain in standby. One way to achieve near-100 percent network uptime is to use HSRP, which provides network redundancy for IP networks, and ensures that user traffic immediately and transparently recovers from first hop failures in network edge devices or access circuits. ✅ Routers: At least two HSRP-supported routers (must be Cisco routers). RFC 2281 describes this protocol in more detail. Basically, each of the routers that provides redundancy for a given gateway address is assigned to a common. The Hot Standby Router Protocol (HSRP) is a Cisco proprietary protocol designed to provide high availability and fault tolerance for IP networks.

    [PDF Version]
  • Can fiber optic cold connectors be used in winter Will it have any impact

    Can fiber optic cold connectors be used in winter Will it have any impact

    The short answer: Fiber handles weather better than copper or satellite because it carries data as pulses of light instead of electrical signals. There is. Cold weather can affect fiber optic cables, but they are generally more resilient to temperature extremes compared to other types of cables, such as copper. After all, many communication networks today rely on these cables to transmit vast amounts of data efficiently. One of the primary concerns is increased attenuation, which refers to the loss of signal strength as it travels through the cable.


SD-WAN, KVM & Optical Insights